Specifications

Ethernet and Fibre Channel Application

463

Synchronization Interfaces

Synchronization Interfaces

For IQS-8510G:

For IQS-8120NGE/IQS-8130NGE and IQS-8525/IQS-8535:

SYNCHRONIZATION INTERFACES

DS1/E1 external input clock interface

Parameter

DS1

E1

Rx level sensitivity (short haul only)

For 772 kHz:

For 1024 kHz:

TERM: 6 dB (cable loss only)

TERM: 6 dB (cable loss only)

Reception bit rate

1.544 Mbit/s ± 50 ppm

2.048 Mbit/s ± 50 ppm

Input jitter tolerance

AT&T PUB 62411, GR-499 section 7.3

G.823 section 7.2

Line coding

AMI and B8ZS

HDB3 and AMI

Input impedance

100 ohms ± 5%, balanced

120 ohms ± 5%, balanced

(resistive termination)
Connector type

BANTAM

BANTAM

Clock out interface

Parameter

Value

Tx pulse amplitude

600 mVpp ± 130 mV

Transmission frequency

LAN

WAN

Clock divider = 16

644.53 MHz

622.08 MHz

Clock divider = 32

322.266 MHz

311.04 MHz

Clock divider = 64

161.133 MHz

155.52 MHz

Output configuration

AC coupled

Load impedance

50 ohms

Maximum cable length

3 meters

Connector type

SMA

External Clock DS1/1.5M

External Clock E1/2M

External Clock E1/2M

Trigger 2 MHz

Tx Pulse Amplitude

2.4 to 3.6 V

3.0 V

2.37 V

0.75 to 1.5 V

Tx Pulse Mask

GR-499 figure 9.5

G.703 figure 15

G.703 figure 15

G.703 figure 20

Typical power dBdsx
+0.6 dBdsx (0-133 ft)

Tx LBO

+1.2 dBdsx (133-266 ft)

Preamplification

+1.8 dBdsx (266-399 ft)
+2.4 dBdsx (399-533 ft)
+3.0 dBdsx (533-655 ft)

Rx Level

TERM:

≤ 6 dB (cable loss only)

TERM: =

≤ 6 dB (cable loss only)

TERM: =

≤ 6 dB (cable loss only)

≤ 6 dB (cable loss only)

Sensivity

(at 772 kHz for T1) DSX-MON:

MON:

≤ 26 dB (20 dB resistive loss

MON:

≤ 26 dB (resistive loss

≤ 26 dB (20 dB resistive loss

+ cable loss

≤ 6 dB)

+ cable loss

≤ 6 dB)

+ cable loss

≤ 6 dB)

Bridge:

≤ 6 dB (cable loss only) Bridge: ≤ 6 dB (cable loss only)

Bridge:

≤ 6 dB (cable loss only)

Transmission Bit Rate 1.544 Mbit/s ± 4.6 ppm

2.048 Mbit/s ± 4.6 ppm

2.048 Mbit/s ± 4.6 ppm

Reception Bit Rate

1.544 Mbit/s ± 50 ppm

2.048 Mbit/s ± 50 ppm

2.048 Mbit/s ± 50 ppm

Intrinsic Jitter (Tx)

ANSI T1.403 section 6.3

G.823

G.823

G.703

GR-499 section 7.3

section 6.1

section 6.1

table 11

Input Jitter

AT&T PUB 62411

G.823 section 7.2

G.823 section 7.2

Tolerance

GR-499 SECTION 7.3

G.813

G.813

Line Coding

AMI and B8ZS

AMI and HDB3

AMI and HDB3

Input Impedance

75 ohms ± 5%,

75 ohms ± 5%,

75 ohms ± 5%,

75 ohms ± 5%,

(Resistive Termination) unbalanced

unbalanced

unbalanced

unbalanced

Connector Type

BNC

a

BNC

a

BNC

BNC