EXFO IQS-8500 Series for IQS-600 User Manual
Page 129

Creating and Starting a Test Case
Ethernet and Fibre Channel Application
115
Ethernet TCP Throughput Test Case
4. Press the TCP Throughput tab and TCP Throughput Configuration
tab.
4a. Select Remote as the TCP Mode.
4b. Enter the IP address of the local module in the Listening IP
Address field.
Create the test on the local module as follow:
1. On the local module, proceed with the test creation as described
above (start with step 1 on page 113 up to step 4 inclusively). However,
in step 4 do the following:
1a. Select Local as the TCP Mode.
1b. Enter the IP address of the remote module in the Remote IP
Address field.
2. For additional configuration parameters, refer to TCP Throughput
3. Press the Start button to start the test.
4. For additional results, refer to TCP Throughput Analysis on page 357.