beautypg.com

EXFO IQS-8500 Series for IQS-600 User Manual

Page 328

background image

RFC 2544 Tabs

314

FTB-8500 Series and FTB-8120NGE/8130NGE

Frame Loss

Test Granularity (%): Select the test granularity. The test granularity is
the percentage interval between each throughput value used for the
test. For example, 10% granularity means that the test will be
performed for 100%, 90%, 80%... of the throughput value. Choices are 1
to 10% (RFC). The default setting is 10%.

Nb of trials to average: Select the number of times the test will be
generated. Choices are 1 to 50 trials. The default setting is 1 trial.

Maximum Rate

TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local: Select
the maximum rate for the test. The default setting is 100 % for
10/100/1000Mbps and 10Gig-E LAN, and 92.8571428571429% for
10Gig-E WAN. P1-to-P2/P2-to-P1 is only available with IQS-8510B.

Select the rate’s unit. Choices are %, and Mbps/Gbps. The default
setting is %.

Minimum Test Time (Seconds): Indicates the minimum time the test
requires to run at best condition. The minimum test time is calculated
and updated once the test is started.

Unit

Interface

Rate

from

to

%

10Base-T

100Base-T

1000Base-T/X

10Gig-E LAN

10Gig-E WAN

1
1
1
1
1

100
100
100
100
92.8571428571429

Mbps

10Base-T

100Base-T

1000Base-T/X

0.1
1
10

10
100
1000

Gbps

10Gig-E LAN

10Gig-E WAN

0.1
0.1

10.0
9.2857142857142865

This manual is related to the following products: