Traffic Analyzer Tabs
176
FTB-8500 Series and FTB-8120NGE/8130NGE
Flow Control
Statistics
Pause Time: Indicates the total number of pause time received from
the link partner.
Last Pause Time: Indicates the last pause time received from the link
partner.
Max. Pause Time: Indicates the maximum pause time received from
the link partner.
Min. Pause Time: Indicates the minimum pause time received from
the link partner.
Unit: Allows the selection of the measurement unit. Choices are
Quanta, ns, μs, ms, and s. The default setting is Quanta.
Pause Frame: The number of received valid flow-control frames.
Frames that have a type/length field equal to 8808h will be counted as
a pause frame.
Abort Frames: Indicates the number of received pause frames with a
Quanta equal to zero; cancelling the pause frames.
Frames TX: Indicates the number of transmitted flow control pause
frames.
Frames RX: Indicates the number of received flow control frames
having a MAC address equal to 01:80:C2:00:00:01 or equal to the MAC