EXFO IQS-8500 Series for IQS-600 User Manual
Page 133
Creating and Starting a Test Case
Ethernet and Fibre Channel Application
119
Fibre Channel BERT Test Case
4. Framing configuration (available with FC Framed Layer 2 only):
4a. Set the network parameters. Refer to
Interface Setup (Fibre Channel) on
page 146 for more information.
4b. Select the Login check box to generate
a login process when pressing on the
Login button.
4c. Select the source and destination World
Wide Name (WWN) addresses. WWN
is only available when the Enable login
check box is selected.
4d. Press the Login button to initiate the Login process with the
selected Advertised BB_Credit (refer to page 147). The capability
to log in is available only with Framed Layer 2 when a successful
link has been established.
4e. Press Next.
5. Pattern configuration:
5a. Set the pattern parameters. Refer to
Pattern TX on page 254 for more
information.
5b. Press Finish to complete the test setup.
The Alarm summary tab is
automatically displayed.
6. For additional configuration parameters,
refer to Stream Generation Tabs on page 201.
7. Press the Start button to start the test.
8. For additional results, refer to Traffic Analyzer Tabs on page 161 and