Traffic Analyzer Tabs

Ethernet and Fibre Channel Application

163

Ethernet TX

PHY Error Injection

Type: The following error is available with both manual and automated
injection modes: Symbol (100/1000Mbps) or Block (10Gbps).

Amount: Allows the selection of the amount of manual error to be
generated. Choices are 1 through 50. The default setting is 1.

Send button: Press Send to manually generate error(s) according to
the error type and the amount of error.

Rate: Press the Rate field to select the rate for the automated error.
Choices are: 1.0E-02, 1.0E-03, 1.0E-04, 1.0E-05, 1.0E-06, 1.0E-07,
1.0E-08, 1.0E-09 or user definable from 1.0E-09 to 1.0E-02. The default
setting is 1.0E-04.

Continuous: Generates the selected error for each generated frame
when the Continuous check box is selected while the On/Off button is
enabled (On). The Continuous check box is cleared by default.

On/Off button: The On/Off button is used to activate/deactivate the
selected automated error at the rate specified or continuously. This
setting is disabled (Off) by default.

MAC Error Injection

Note: MAC Error Injection is available with Framed Layer 2 only.

Type: The following error is available with both manual and automated
injection modes: FCS.

Amount: Allows the selection of the amount of manual error to be
generated. Choices are 1 through 50. The default setting is 1.

Send button: Press Send to manually generate error(s) according to
the error type and the amount of selected error.