Multi-meter Tests

88

AXS-200/635i

Multi-meter

Noise Metallic

The Noise Metallic test allows you to
measure the amount of unwanted or
disturbing energy introduced into a
loop from man-made and natural
sources.

Each parameter is described below.

³

Termination is either BRIDGING if
the unit uses high bridging
impedance when the cable is
active or terminated by other external equipment, or TERMINATED if
the unit uses normal test impedance termination.

³

Noise Filter is either PSOPHOMETRIC for ITU standard or C-MESSAGE
for ANSI standard.

To start/stop the test:
1.
Press the up/down arrow keys to highlight the desired test parameter.

2. Press

to open the list.

3. Press the up/down arrow keys to highlight the desired value, then press

to select it.

4. Select other parameters as required.

5. Press

to start/stop the test.

Test results are displayed on the screen as they are completed.