beautypg.com

Pp g p, Technical specifications, Copper, vdsl2, adsl2+ and ip triple-play test set – EXFO VDSL2 User Manual

Page 265

background image

Technical Specifications

Copper, VDSL2, ADSL2+ and IP Triple-Play Test Set

257

pp

g

p

NOTES

a. At 23

°C ± 1 °C on batteries, unless otherwise specified.

b. Characteristics are subject to instrument noise floor (approx.

70 dBm). Levels below

70 dBm can be measured using the PSD noise test.

c. Does not include the uncertainty due to VOP.

RECEIVER CHARACTERISTICS

b

Receive frequency

200 Hz to 10 kHz, resolution 1 Hz

Receive frequency

10 kHz to 20 kHz, resolution 10 Hz

Receive frequency

20 kHz to 30 MHz, resolution 1 kHz

Frequency uncertainty (accuracy)

±(50 ppm + 0.5 Hz)

Receive level (dBm)

–90 to +10 at 100

Ÿ or 135 Ÿ, resolution 0.1 dB

–100 to +10 at 600

Ÿ, resolution 0.1 dB

Level uncertainty (accuracy)

±1.0 dB for 200 Hz to 20 kHz at 0 dBm
±1.0 dB for 20 kHz to 30 MHz at 0 dBm

Impedance (

Ÿ)

100, 135, 600 and bridging (100 k

Ÿ)

TRANSMITTER CHARACTERISTICS

Transmit frequency

200 Hz to 20 kHz, resolution 1 Hz steps

Transmit frequency

20 kHz to 30 MHz, resolution 1 kHz steps

Transmit level (dBm)

–20 to +5 at 600

Ÿ for 200 Hz to 499 Hz

–20 to +10 at 600

Ÿ for 500 Hz to 20 kHz

–10 to +10 at 100/135

Ÿ for 20 kHz to 30 MHz

Frequency uncertainty (accuracy)

±(50 ppm + 0.5 Hz)

Level uncertainty (accuracy)

±0.6 dB

200 Hz to 20 kHz at 0 dBm

±1 dB

20 kHz to 2.2 MHz

±2 dB

2.2 MHz to 17 MHz

±3 dB

17 MHz to 30 MHz

Impedance (

Ÿ)

100, 135 and 600

VF NOISE MEASUREMENT

Range (dBm)

0 to –90, subject to instrument noise floor

Uncertainty (accuracy) (dB)

±1

Filters

None, 3 kHz flat, C-message, psophometric, notched and D filter (IEEE 743-1995)

VF IMPULSE NOISE

Low threshold (dBm)

0 to –40, in 1 dB steps

Mid threshold

Low threshold plus separation

High threshold

Mid threshold plus separation

Separation (dB)

1 to 6, in 1 dB steps

Dead time (ms)

125

Filters

None, 3 kHz flat, C-message, psophometric, notched and D filter (IEEE 743-1995)

Counter

Maximum 999 for each threshold

Timer

1 minute to 24 hours, default is 15 minutes

POWER INFLUENCE (NOISE TO GROUND)

Noise range (dBm)

–60 to +10

Uncertainty (accuracy) (dB)

±1.0

Level uncertainty (accuracy) (dB)

±1.0 at –60 dBm

VF LONGITUDINAL BALANCE

Frequency (Hz)

1004

Frequency uncertainty (accuracy) (ppm)

±50

Level range (dB)

0 to 80

Level uncertainty (accuracy) (dB)

±1

TIME-DOMAIN REFLECTOMETRY (TDR)

Mode

Fully automatic operation with location of most significant events

Distance range (m)

8 to 6000 (25 ft up to 20 000 ft)

Pulse width

15 ns to 20

—s

Test signals

Sine wave, compensated sine wave, half-sine wave and square wave

Amplitude

7.5 V p-p on cable, 9 V p-p open circuit

Velocity of propagation (VOP)

0.400 to 0.999 or 120 m/

—s to 299 m/—s

Distance uncertainty

c

(accuracy) (m)

±(1.4 m + 2 % x distance) or ±(4.5 ft + 2 % x distance)

Units

Feet and meters

Horizontal scale (m)

Automatic or 30 (100 ft), 300 (1000 ft), 600 (2000 ft), 1500 (5000 ft), 3000 (10 000 ft), 6000 (20 000 ft),
13 500 (45 000 ft) and 15 000 (50 000 ft)

FREQUENCY-DOMAIN REFLECTOMETRY (FDR)

Distance range (m)

1.5 to 5000 (5 ft to 18 000 ft)

Velocity of propagation (VOP)

0.400 to 0.999 or 120 m/

—s to 299 m/—s

Distance uncertainty (accuracy) (m)

±3 (3 to 1000), ±15 (1000 to 1500), ±50 (1500 to 5000)

Units

Feet and meters

LOAD COIL DETECTION

Count

Five

Plot (kHz)

Up to 10

Distance range (m)

Up to 8000 (up to 27 000 ft)

SINGLE-END FREQUENCY RESPONSE (ATTENUATION)

Distance range (m)

70 to 5000 (200 ft to 16 000 ft)

Frequency range

4.3 kHz to 30 MHz

Frequency uncertainty (accuracy)

±50 ppm

Level uncertainty (accuracy) (dB)

2 dB, 4 dB at 30 MHz

Resolution (dB)

0.1

Horizontal scale (MHz)

ADSL2+ = 2.208, VDSL2-12 = 12, VDSL2-17 = 17.66, VDSL2-30 = 30

Vertical scale (dB)

0 to +100