Line status – EXFO VDSL2 User Manual
Page 205
IPTV Analysis
Copper, VDSL2, ADSL2+ and IP Triple-Play Test Set
197
Reading Results
Line Status
The Line Status tab allows you to view the conditions of the line under test
which was configured in the connection setup.
The available test results are the
following:
³
Line Status displays Connected
when the unit and the DSLAM
have successfully connected and
negotiated applicable data rates
for the particular connection
under test. During negotiation with
the DSLAM, the value changes
from Booting/Activate/Handshaking/Full Initialization to Connected.
³
Operational Mode is the DSL mode of operation as negotiated
between the unit and the DSLAM.
³
CO VendorID is a unique 4-digit alphanumeric identifier of the DSL
chipset manufacturer used on the central office (CO) side.
³
CO Version is the version number of the unique alphanumeric
identifier of the DSL chipset used on the CO side.