Common parameters – EXFO VDSL2 User Manual

Page 37

background image

Auto Tests

Copper, VDSL2, ADSL2+ and IP Triple-Play Test Set

29

Configuring CQ Auto Tests

Common Parameters

The Common Param. tab allows you to
set up parameters common to all tests
in the auto test function.

Each parameter is described below:

³

Cable Type defines the gauge of
the cable in use. If wire gauge is
measured in AWG units, the
available choices are: AUTO,
19 AWG, 22 AWG, 24 AWG, or
26 AWG. For mm gauge wire, the available choices are: AUTO,
0.32 mm, 0.40 mm, 0.50 mm, 0.60 mm, 0.80 mm, 0.90 mm, or
1.20 mm.

³

Temperature specifies the temperature of the cable under test in
either F (Fahrenheit) or C (Celsius) units.

³

Isolation Test Time(sec) specifies the duration of the isolation test.

³

Input Impedance displays the input impedance in the loop. The
available choices are: >1 MOhm, 100 KOhm.

To set parameter values:
1.
Press the up/down arrow keys to highlight the desired parameter.

2. Press

to display the list or select the value.

3. Press the up/down arrow keys to highlight the desired value.

OR

4. Press the left arrow key to erase the existing value, and then use the

alphanumeric keypad to enter a value. To cancel the entry, press

.

5. Press

to accept the value.