beautypg.com

13 iptv analysis, Reading results, Test summary – EXFO VDSL2 User Manual

Page 203

background image

Copper, VDSL2, ADSL2+ and IP Triple-Play Test Set

195

13 IPTV Analysis

The IPTV Analysis test functionality provides all the required information
for the installation, maintenance, and/or troubleshooting of video services,
including IPTV, delivered over DSL.

To view the available tabs:
Press the left/right function arrows on each side of the F1, F2, and F3 keys.

Reading Results

Test Summary

The Test Summary tab allows you to view the PASS/FAIL status and
Details of all the tests configured for the DSL and Ethernet layers over
which the IPTV service is being delivered. If a measured value is out of the
threshold range configured for the IPTV analysis setup, the Test Summary
screen displays a FAIL message.

The available test results are the
following:

³

Line Status displays Booting,
Activate, Handshaking,
Full Initialization to Connected
for the particular line connection
under test.

³

WAN Status displays whether the
unit is Connected to the wide area
network, or in idle mode.

³

IP PacketLoss is the total number of lost video packets within the
threshold range.

³

IP PacketJitter is the variance of the real-time transport protocol (RTP)
data packet inter-arrival time.