Series 5000 Router

(Router 5000 or FT Router

5000)

A Side

RST~

+ 3.3 V

+ 3.3 V

100 pF

100 pF

+ 3.3 V

To other

devices

Series 5000 Router

(Router 5000 or FT Router

5000)

B Side

RST~

Reset

Figure 16. Reset Circuit – Series 5000 Router for Both Halves

If your router uses a Series 3100 half-router for one of its sides, you can connect

the Router 5000’s RST~ pin to the Series 3100 RESET~ pin, as shown in as

shown in Figure 17, using the Series 3100 Smart Transceiver’s +5 V power

supply for the Reset switch, LED, diode clamps, and EMC capacitors.