S

YSTEM

M

ESSAGES

System Message Summary

Transmit rate increased to : Access , DLCI
The effective transmit rate has been increased to the indicated rate for the indicated DLCI under the
indicated access.

Transmit rate reduced to CIR : Access , DLCI
The effective transmit rate has been limited to the Committed Information Rate which is the rate
for the indicated DLCI under the indicated access.

Type mismatch of configured & installed adapter # ’x’
Configuration mismatch between the indicated adapter and the resource that was configured. The
system resource configuration should be corrected.

Unable to add dynamically-obtained device data into Device Table
The System authentication type is configured to obtain device information off-node. If such
information cannot be stored internally due to a temporary resource shortage, the call is dropped.

Unable to allocate IPX spoofing memory. IPX spoofing is being performed in a degraded mode.
The memory required by the IPX spoofing feature could not be allocated. The IPX spoofing code
will continue to run but it will run in a degraded mode. The default IPX spoofing options will
always be used when a connection is down to a device.

Unable to allocate port structure for port with address
Contact your Distributor or Customer Support.

Unable to allocate unnumbered wan port for device
Contact your Distributor or Customer Support.

Unable to complete Bridge Dial Out call: Insufficient information configured for Dial Out Device
Verify that Bridging and Make Calls for Bridge Data are enabled at the device level.

Unable to communicate with encryption board
Try again. If the problem persists, you may have a faulty encryption board. Replace the board.

Unable to Decrypt Datagram
An incoming datagram could not be decrypted. Verify encryption parameters on both nodes.

Unable to dynamically determine incoming call usage: Call Released.
This message refers to an incoming analog call which is going through the digital modem. The
digital modem has transferred the call to the AUD to determine type of call. The AUD did not
recognize any PPP LCP frames to transfer to the PPP stack, nor did it recognize the four carriage
returns it requires (within 5 seconds of connection) for remote analog console access.

If you are attempting remote analog console access, be sure to press the carriage return four times
within 5 seconds of making the connection.

Unable to get Digital Modem resource to place call
A Digital Modem dial-out call was attempted, and the system was unable to open a resource to
place the call. Using the

modem status

command, check to ensure that there are usable modems

available. If there are, and the problem persists, contact your Distributor or Customer Support.