470 CyberSWITCH
system to start dialing. Contact the telephone company and ensure that the line is configured for
wink-start.
RBS: Unexpected event chan =
configured correctly and that it is using the expected RBS protocol. Excess noise on the line may
also cause this event.
Read 0 bytes from file
Distributor or Customer Support.
Ready for XModem Download -
the system the last time it was attempted.
Reattempting to Install File Set into Flash Memory
The SSB is re-attempting to install the FileSet. The Flash File System may have been corrupted when
attempting to install the FileSet the first time. In the meantime, the Flash File System has been
formatted.
Rebooting...
The system is going to wait until the WatchDog timer expires, which causes the entire system to
reboot.
Received charge amount -
charge for this call is indicated in the charge amount parameter.
Received CLLM while PVC for DLCI
associated with the indicated DLCI. However, this PVC is in the indicated state and as such is
already acting on a previous network condition notification.
Remote peer ID discrepancy
The On-node Device Table and the remote end of the connection disagree on the identity of the
remote end. Check configuration, and then reboot the remote device. If problem persists, contact
your Distributor or Customer Support.
Replace Lithium Battery: Contact your Representative
If this message is displayed in the log messages, contact your Distributor or Customer Support
before you power off your system.
Requested channel not available -
call will be retried over a different line if possible.
Reserved signal
This message is informational only and is used to indicate additional details on the
received in the “call progress” information message.