Workgroup Remote Access Switch 343

C

ONFIGURING

O

THER

A

DVANCED

O

PTIONS

Log Options

C

ONNECTION

ID

This field is used to correlate all records involving a particular ISDN connection. The field is an
unsigned long hexadecimal integer. It begins at zero when the system is loaded and increments by
one to 0FFFFFFFF hex, at which point it wraps back to zero. This provides for somewhat over four
billion connections before a connection Id is re-used.

D

ATA

R

ATE

This field indicates the data rate for a B channel. The possible values are 56 Kb, 64 Kb and 384 Kb.

D

URATION

This field reflects the time that a connection is active; it is presented in hours, minutes and seconds.
The precise meaning varies somewhat for a successful connection versus a call rejection.

E

VENT

T

YPE

This field indicates what type of event the associated message is reporting. The possible values are
‘CONNECT’, ‘DISCONNECT’, ‘REJECT’, ‘SYSTEM UP’ and ‘CDR VERIFY’.

NAS N

AME

NAS Name (Network Access Server Name) contains the System Name of the system logging the
message.

P

HONE

N

UMBER

On incoming calls this field contains the Calling Line Id of the caller if the information is available
(some switches do not provide Calling Line Id). On outgoing calls, this field contains the phone
number of the remote device that the system is calling.

R

EMOTE

D

EVICE

N

AME

This field contains the name of the remote device, if available.

S

LOT

, L

INE

AND

B

EARER

This field identifies the slot (or resource), the line and the bearer channel used for the associated
connection.

T

IME

STAMP

The field contains the time and date. The meaning of this field varies depending upon the report.

Connect Event Report Contents

On a connect event, records 1 through 3 are used. The event type is CONNECT. The timestamp
reflects the time that the ISDN connect message was received from the switch. An incoming phone
number is displayed if it is provided by the telephone switch. Not all switches provide calling line
identification. A phone number is always displayed for outbound calls.

The following are example connect event reports:

example 1:

Chicago-Schaumburg 00000001 CONNECT 1 OF 3 MonroeCounty PORT 1/1/1
Chicago-Schaumburg 00000001 CONNECT 2 OF 3 IN FROM 3135551212
Chicago-Schaumburg 00000001 CONNECT 3 OF 3 64Kb 08/16/95 23:11:55