beautypg.com

Cabletron Systems CSX1000 User Manual

Page 435

background image

Workgroup Remote Access Switch 435

S

YSTEM

M

ESSAGES

System Message Summary

Bridge is operating in RESTRICTED mode
Bridge is operating in UNRESTRICTED mode
One of the above messages will be displayed to indicate the configured Bridge mode of operation.

Calculating CRC’s.....
An X-Modem transfer has been completed and the received data is being checked for integrity.

Call control detected near end problem - Slot= Port=
The system detected a problem when initiating a call over the indicated line. The call will be retried
over a different line if possible.

Calling Line ID Failure, Duplicate ID -
A call has come in for a device that is using Calling Line Id (CLID) as the only authentication
method, and the given CLID is not unique across all devices.

Calling Line ID Security Failure
The system has rejected a device due to a mismatch between the Calling Line Id presented by the
caller and the Calling Line Id in the on-node device database or obtained via an off-node
authentication server such as RADIUS.

Calling Line ID Security Failure , Device:
The system has rejected a device due to a mismatch between the Calling Line Id presented by the
caller and the Calling Line Id in the on-node device database or obtained via an off-node
authentication server such as RADIUS. The device’s name is also contained within the database.

Calling Line ID Security Failure - off-node authentication server not supported
The system authentication type is configured to obtain device information off-node, for example
from a RADIUS server; however, such transactions are not yet supported when Calling Line Id
Security is enabled.

Call_ID in use in HOST_CALL_REQUEST
The system software sent a message to the RBS state machine that the state machine was unable to
recognize or the information was incorrect. If this message is displayed in the log messages, contact
your Distributor or Customer Support.

Call Rejected, Maximum Bandwidth already in place to Device Id
An incoming call was rejected because the Maximum Data Rate parameter was exceeded for the
indicated device. The Maximum Data Rate parameter can be configured for PPP devices under the
configuration utility CFGEDIT or through the Manage Mode.

Call Rejected, No Called TN IE
The switch did not deliver an Information Element for the call. This problem normally occurs if you
are connected to a point-to-point line and have the System configured for a multipoint line. If you
are connected to a multipoint line and get this message, call your phone company and report the
problem.

Call Restrictions have been disabled by user command
The user has disabled Call Restrictions via the

callrest off

Dynamic Management command.

Call Restrictions have been enabled by user command
The user has enabled Call Restrictions via the

callrest on

Dynamic Management command.