Verifying a dedicated connection, Verifying a frame relay connection – Cabletron Systems CSX1000 User Manual
Page 356

USER’S GUIDE
356 CyberSWITCH
V
ERIFYING
A
D
EDICATED
C
ONNECTION
To verify a dedicated connection to the CyberSWITCH, the WAN lines that are connected to the
system must be available for use, and the routing option must be properly initialized.
To verify that you have a dedicated connection:
1.
View the system messages by entering the following console command:
dr
2.
Look for the following system message among the displayed messages:
Layer 1 sync not seen - Slot= endpoint suffix> If the above message appears, a physical problem has been detected on the indicated line. If the above message does not appear in the displayed messages, proceed to the next step. 3. Look for the following system message among the displayed messages: Dedicated connection to device Port= If the above message is displayed, the dedicated connection is functioning. If the following message appears, the dedicated connection is not functioning. Dedicated connection down: Slot= Refer to in the Problem Diagnosis chapter. Because all remote devices that use dedicated connections are PPP devices, follow the described set-up procedure, then . V ERIFYING A F RAME R ELAY C ONNECTION To verify a frame relay connection to the CyberSWITCH, the WAN lines that are connected to the Enter the frame relay stats command at the administration console. If the statistics display appears, the frame relay subsystem should be operational. If the following message is displayed, No Frame Relay Accesses configured Enter the cs command at the administration console. The device name for the associated PVC should appear in the list of connected sites. If you receive the above message, or if the device name for the associated PVC does not appear in of the Problem Diagnosis chapter.
Check for a proper connection to the CyberSWITCH and to the NT1 or CIU. If the NT1 or CIU
appears to be functioning properly, call your carrier service and report the problem.
skip to the step specific for
System must be available for use, and the routing option must be properly initialized. To verify a
connection, the a remote device must have a connection established.
frame relay is not configured:
the list of connected sites, then refer to