Page 4: Location, Receiving, moving, and storage 1. general (cont'd)

background image

Form I-MAPS II, Page 4

1.3 Warranty

Refer to limited warranty information on the warranty form in the "Literature

Bag" shipped with this system. If an optional extended warranty applies, keep

the extended warranty information for future reference and verification of war-

ranty.

Massachusetts

Requirements

If being installed in the Commonwealth of Massachusetts, this unit must be

installed by a licensed plumber or licensed gas fitter.

California Warning

Label

If a gas-fired heat section is included and the system is being installed in the

state of California, the installer MUST attach a warning label on the outside of

the heat section access panel. The California Warning label is shipped in the

"Literature Bag". If installation is in California, select a dry, clean location on the

heat section access panel and adhere the label.

3. Receiving,

Moving, and

Storage

1. General (cont'd)

1.4 Installation Codes

These packaged systems are certified by ITS to Heating Cooling Equipment

(latest edition), UL 1995 / CAN/CSA C22.2 No. 236. Electrical characteristics

are shown on the system rating plate. All cooling and dehumidification reheat

cycle circuits are factory-charged with R-22 or R407C refrigerant.
Model RDCA and Model RDDA include a gas heat section. The system

includes a power-vented gas-fueled duct furnace. The gas-fired furnace using

the Reznor

®

T

CORE

combustion system is available in 13 sizes from 100 to

700 MBH for use with either natural or propane gas. The furnace is certified by

ITS to both ANSI Z83.8b and CSA 2.6b-M. The ETL label, type of gas, and the

firing rate are shown on the heat section rating plate.
Model RECA and Model REDA include an electric heat section. The electric

heat section is available in 21 sizes from 5 to 88 kw with single or three-stage

control. Refer to the system rating plate for electrical requirements. Models

RECA and REDA require only a single-point electrical supply.

Approval and

Installation Codes

2. Location

All of these packaged systems are designed to be mounted on a roof or slab

using a manufacturer designed curb. Both downflow and horizontal curbs are

available.
When the unit is being placed on a roof, location depends on the roof struc-

ture.
Position the curb so that the air inlet of the unit will not be facing into the pre-

vailing wind.
Always comply with the clearances in Paragraph 4.3.
For condensate drainage and proper operation, it is important the installation

be level.

This system was test operated and inspected at the factory prior to crating

and was in operating condition. If the equipment has incurred any damage in

shipment, document the damage with the carrier and immediately contact your

Reznor distributor.

3.1 Receiving and Moving