beautypg.com

3 inlet air hood, Mechanical (cont'd) – Reznor MAPS II Unit Installation Manual User Manual

Page 20

background image

Form I-MAPS II, Page 20

To avoid possible damage, it is recommended that the outside air hood be

installed after the system has been placed on the roof. The air hood should be

installed before the blower is operated. Do not install the hood while the system

is in operation.

All screw ends should be inside the air hood. Remove plastic film from painted

parts before installing. Refer to the illustration that applies:

FIGURE 10A for Cabinet Sizes A and B without a power exhaust option

FIGURE 10B for Cabinet Size A with a power exhaust option

FIGURE 10C for Cabinet Size B with a power exhaust option

FIGURE 10D for Cabinet Size C with or without a power exhaust option

(

NOTE: See Model Size/Cabinet Size cross-reference tables in the Appendix

on page 58.)
Instructions (apply to all FIGURES except where noted):

1. Install Top Panel - On the air inlet of the cabinet, remove and save the

factory-installed screws attaching the system top. Slide the hood

top panel

underneath the edge of the cabinet top.

The edge of the hood top panel

must be between the cabinet top and the end panel. Reinsert all of the

sheetmetal screws.

2. Install Left Side Panel (right when facing the unit) - Locate the vertical

row of cabinet screws to the right of the opening that attach the condenser

section. Remove and save those screws.

Position the hood left side panel under and to the

inside of the hood top

panel. Reinsert the screws to attach the side panel.

Attach the hood side panel to the hood top with sheetmetal screws.

3. Install Right Side Panel (left when facing the unit) - Position the hood

right side panel under and to the inside of the hood top panel. Attach to the

unit using the required number of

self-drilling screws.

4. FIGURE 10C - Install Top Panel Slope Section - Position the slope panel

against the top panel and over the side panels. Attach to the top panel and

both sides with sheetmetal screws.

5. Install Bottom Support - Position the hood bottom support so that it is to

the

inside of the two side panels.

FIGURES 10A and 10D - Attach to the cabinet using the required number

of

self-drilling screws. Attach to both side panels with sheetmetal screws.

FIGURES 10B and 10C - Attach to both side panels with sheetmetal

screws.

6. Install the Filter Assembly

FIGURE 10A, Cabinet Sizes A and B without a power exhaust option -

Attach the center support and the two side filter angles. Attach the filter

spacer with wing screw receptacle. Position the four filters in the opening.

Secure the filters with the filter clamp and the wing screws.

FIGURES 10B and 10C, Cabinet Size A or B with a power exhaust

option - Install the filter frame with filters in place. Position the filter frame

assembly in the inlet opening of the hood. Attach at the front and back

holes with 1/2" sheetmetal screws. Insert a 3/4" sheetmetal screw at each

of the center holes (one on each side).

6.3 Inlet Air Hood

The outside air inlet hood is a weatherized hood with permanent aluminum

filters, designed to be field assembled and installed around the horizontal inlet

air opening of the cabinet.

CAUTION: It is recommended that the inlet to the outside air hood

NOT be facing into the prevailing wind. Allow 14" minimum clearance

from the bottom of the air hood to the mounting surface.

Option AS16 or

AS19, Inlet Air

Hood, Installation

Instructions

Installation NOTE:

If equipped with

a power exhaust

option, attach the

power exhaust

hood(s) before

installing the outside

air hood. See

Paragraph 9.2,

pages 38-39.

NOTES:
- Inlet air hood painted

parts are shipped with a

protective plastic cover-

ing. As parts are being

installed, remove the

protective plastic cover-

ing.

- Select screws care-

fully. Use sheetmetal

screws (slotted head

with straight tip) when

holes in the cabinet are

provided. Use self-drill-

ing screws (head is not

slotted with drill-type tip)

when cabinet holes are

not provided.

6. Mechanical