compressor circuit breaker protection

Analogue outputs (PWM)

EVF818

evaporator fan

(1)

Digital outputs (electromechanical relays; A res. @

250 VAC)

EVF818

compressor

30 A

defrosting

8 A

evaporator fan

(1)

condenser fan

8 A

door heating elements

8 A

needle probe heating

16 A

cabinet light/UV light

8 A

pump down valve/alarm

8 A

Communication port

EVF818

TTL type serial port

RS-48 serial port with MODBUS communication protocol

Other features

EVF818

IP65 protection rating of the user interface

IP65

clock

signal buzzer and alarm

management of three types of backlight

management of blast chilling and storage/deep freezing

and storage cycles

management of temperature/time controlled operation

cycles

hard/soft operating cycles management