EVCO EVF818P9 User Manual
Page 37
EVCO S.p.A.
EVF818 | Installer manual ver. 1.0 | Code 144F818E104
page 37 of 76
Inf.
Meaning
8
the critical value is 8 °C /8 °F
StA
the display is about to show the date and time the alarm occurred
y11
the alarm occurred in 2011 (continue...)
n03
the alarm occurred in the month of March (continue...)
d26
the alarm occurred on 26 March 2011
h16
the alarm occurred at 16:00 (continue...)
n30
the alarm occurred at 16:30
dur
the display is about to show the duration of the alarm
h01
the alarm had duration of 1 h (continue ...)
n15
the alarm had duration of 1 h and 15 minutes
AH3
the alarm code selected
the displays each piece of information for 2 s.
Operate as follows to abandon the succession of information:
7.
Press and release the START/STOP key: the display will show the alarm code selected again.
Operate as follows to exit the procedure:
8.
Abandon the succession of information.
9.
Press and release the UP or DOWN key until the display shows the magnitude indicated in paragraph 5.3 "The
display" or do not operate for 60 s.
8.3
Deleting the information relative to the HACCP
alarms
Operate as follows:
1.
Make sure that the keyboard is not locked and that no procedure is in progress.
2.
Hold the DOWN key down for 2 s: the 3 digit display will show the first label available.
3.
Press and release the UP or DOWN key to select “rLS”.
4.
Press and release the BLAST CHILLING key: the 4 digit display will show “0”.
5.
Press and release the UP or DOWN key within 60 s to set “149”.
6.
Press and release the BLAST CHILLING key or do not operate for 60 s: the 4 digit display will show “- - - -”
flashing for 4 s and the HACCP LED will switch off, after which the device will automatically exit the procedure
and the display will show the magnitude indicated in paragraph 5.3 “The display”.
If the device has not memorised any information relative to the HACCP alarms, the “rLS“ label will not be displayed.