Pr3

Condenser probe error.

Solutions:

-

the same as the cabinet probe error (“Pr1” code) but relative to the condenser probe.

Main consequences:

-

the condenser fan will operate parallel to the compressor

-

the overheated condenser alarm (“COH” code) will never be activated

-

the compressor blocked alarm (“CSd” code) will never be activated

-

the alarm output will be activated.

Pr4

Needle probe error 1.

Solutions:

-

the same as the cabinet probe error (“Pr1” code) but relative to the needle probe 1.

ain consequences if parameter P3 is set at 1:

-

if the error occurs during the “stand-by” status, temperature-controlled operating cycles will

be started by time-control

-

if the error occurs during temperature-controlled blast chilling, this will have duration of the

time set by parameter r1

-

if the error occurs during temperature-controlled deep freezing, this will have duration of

the time set by parameter r2

-

if the error occurs during needle probe heating, this operation will be interrupted.

-

the alarm output will be activated.

ain consequences if parameter P3 is set at 2 or at 3:

-

the device will not use needle probe 1.

Pr5

Needle probe error 2.

Solutions:

-

the same as the cabinet probe error (“Pr1” code) but relative to the needle probe 2.

Main consequences:

-

the device will not use needle probe 2.

Pr6

Needle probe error 3.

Solutions:

-

the same as the cabinet probe error (“Pr1” code) but relative to the needle probe 3.

Main consequences:

-

the device will not use needle probe 3.