beautypg.com

9compressor operating hours count, 1 display of compressor operating hours, 2 deleting the compressor operating hours – EVCO EVF818P9 User Manual

Page 38

background image

EVCO S.p.A.

EVF818 | Installer manual ver. 1.0 | Code 144F818E104

page 38 of 76

9

COMPRESSOR OPERATING HOURS COUNT

9.1

Display of compressor operating hours

Operate as follows:

1.

Make sure that the keyboard is not locked and that no procedure is in progress.

2.

Hold the DOWN key down for 2 s: the 3 digit display will show the first label available.

3.

Press and release the UP or DOWN key to select “CH”.

4.

Press and release the BLAST CHILLING key: the 4 digit display will show the compressor operating hours.

Operate as follows to exit the procedure:

5.

Press and release the BLAST CHILLING key or do not operate for 60 s: the 4 digit display will switch off.

6.

Press and release the UP or DOWN key until the display shows the magnitude indicated in paragraph 5.3 "The

display" or do not operate for 60 s.

9.2

Deleting the compressor operating hours

Operate as follows:

1.

Make sure that the keyboard is not locked and that no procedure is in progress.

2.

Hold the DOWN key down for 2 s: the 3 digit display will show the first label available.

3.

Press and release the UP or DOWN key to select “rCH”.

4.

Press and release the BLAST CHILLING key: the 4 digit display will show “0”.

5.

Press and release the UP or DOWN key within 60 s to set “149”.

6.

Press and release the BLAST CHILLING key or do not operate for 60 s: the 4 digit display will show “- - - -

flashing for 4 s and the HACCP LED will switch off, after which the device will automatically exit the procedure

and the display will show the magnitude indicated in paragraph 5.3 “The display”.