EVF818 | Installer manual ver. 1.0 | Code 144F818E104
page 18 of 76
-
the 4 digit display:
-
will show the temperature of the cabinet.
5.4
Cabinet temperature display
Operate as follows:
1.
Make sure that the keyboard is not locked and that no procedure is in progress.
2.
Hold the DOWN key down for 2 s: the 3 digit display will show the first label available.
3.
Press and release the UP or DOWN key to select “Pb1”.
4.
Press and release the BLAST CHILLING key: the 4 digit display will show the cabinet temperature.
Operate as follows to exit the procedure:
5.
Press and release the BLAST CHILLING key or do not operate for 60 s: the 4 digit display will switch off.
6.
Press and release the UP or DOWN key until the display shows the magnitude indicated in paragraph 5.3 "The
display" or do not operate for 60 s.
5.5
Evaporator temperature display
Operate as follows:
1.
Make sure that the keyboard is not locked and that no procedure is in progress.
2.
Hold the DOWN key down for 2 s: the 3 digit display will show the first label available.
3.
Press and release the UP or DOWN key to select “Pb2”.
4.
Press and release the BLAST CHILLING key: the 4 digit display will show the evaporator temperature.
Operate as follows to exit the procedure:
5.
Press and release the BLAST CHILLING key or do not operate for 60 s: the 4 digit display will switch off.
6.
Press and release the UP or DOWN key until the display shows the magnitude indicated in paragraph 5.3 "The
display" or do not operate for 60 s.
If the evaporator probe is not enabled, i.e. if parameter P4 is set at 0, the “Pb2“ label will not be displayed.
5.6
Condenser temperature display
Operate as follows:
1.
Make sure that the keyboard is not locked and that no procedure is in progress.
2.
Hold the DOWN key down for 2 s: the 3 digit display will show the first label available.
3.
Press and release the UP or DOWN key to select “Pb3”.
4.
Press and release the BLAST CHILLING key: the 4 digit display will show the condenser temperature.
Operate as follows to exit the procedure:
5.
Press and release the BLAST CHILLING key or do not operate for 60 s: the 4 digit display will switch off.
6.
Press and release the UP or DOWN key until the display shows the magnitude indicated in paragraph 5.3 "The
display" or do not operate for 60 s.
If the condenser probe is not enabled, i.e. if parameter P5 is set at 0, the “Pb3“ label will not be displayed.