5user interface, 1 foreword, 2 switching the device on/off – EVCO EVF818P9 User Manual
Page 17: 3 the display

EVCO S.p.A.
EVF818 | Installer manual ver. 1.0 | Code 144F818E104
page 17 of 76
5
USER INTERFACE
5.1
Foreword
The following operating status exist:
-
the “off” status (the device is not powered)
-
the “stand-by” status (the device is powered and is off)
-
the “on” status (the device is powered, is on and is in stand-by for the start-up of an operating cycle)
-
the “run” status (the device is powered, is on and an operating cycle is in progress).
Hereon, the term "device switch-on" means the passage from the "stand-by" status to the "on" status. the term
"switch-off" means passage from the "on" status to the "stand-by" status.
If a power cut occurs during the "stand-by" status or during the "on" status, the device will re-propose the same
status when the power supply is restored.
If a power cut occurs during the "run" status, the device will operate as follows when this is restored:
-
if a temperature-controlled blast chilling or deep freezing operation was in progress, these will be started again
from the beginning
-
if a time-controlled blast chilling or deep freezing operation was in progress, these will be started again from
the moment the power supply was cut-off
-
if storage was in progress, this will be re-proposed.
5.2
Switching the device on/off
Operate as follows:
1.
Make sure that the keyboard is not locked and that no procedure is in progress.
2.
Hold the ON/STAND-BY key down for 2 s: the LED will switch on/off.
5.3
The display
All displays are off during the "off" status and during the "stand-by" status.
During the "on" state:
-
the 1 digit display is off.
-
the 3 digit display:
-
will display the blast chilling end temperature if a temperature-controlled blast chilling cycle has been
selected or the deep freezing end temperature if a temperature-controlled deep freezing cycle has been
selected.
-
will display the blast chilling duration if a temperature-controlled blast chilling cycle has been selected or
the deep freezing duration if a temperature-controlled deep freezing cycle has been selected.
-
the 4 digit display:
-
will display the work set-point during blast chilling if temperature-controlled blast chilling has been
selected or the work set-point during deep freezing if temperature-controlled deep-freezing has been
selected.
-
will be off if time-controlled blast chilling or time-controlled deep freezing has been selected.
During the "run" state:
-
the 1 digit display shows the program number if there is one in progress.
-
the 3 digit display:
-
will show the temperature detected by the needle probe if a temperature-controlled blast chilling or deep
freezing cycle is in progress
-
will display the residual blast chilling time if time-controlled blast chilling is in progress or the residual
deep freezing time if time-controlled deep freezing is in progress