EVCO S.p.A.

EVF818 | Installer manual ver. 1.0 | Code 144F818E104

page 17 of 76

5

USER INTERFACE

5.1

Foreword

The following operating status exist:

-

the “off” status (the device is not powered)

-

the “stand-by” status (the device is powered and is off)

-

the “on” status (the device is powered, is on and is in stand-by for the start-up of an operating cycle)

-

the “run” status (the device is powered, is on and an operating cycle is in progress).

Hereon, the term "device switch-on" means the passage from the "stand-by" status to the "on" status. the term

"switch-off" means passage from the "on" status to the "stand-by" status.

If a power cut occurs during the "stand-by" status or during the "on" status, the device will re-propose the same

status when the power supply is restored.

If a power cut occurs during the "run" status, the device will operate as follows when this is restored:

-

if a temperature-controlled blast chilling or deep freezing operation was in progress, these will be started again

from the beginning

-

if a time-controlled blast chilling or deep freezing operation was in progress, these will be started again from

the moment the power supply was cut-off

-

if storage was in progress, this will be re-proposed.

5.2

Switching the device on/off

Operate as follows:

1.

Make sure that the keyboard is not locked and that no procedure is in progress.

2.

Hold the ON/STAND-BY key down for 2 s: the LED will switch on/off.

5.3

The display

All displays are off during the "off" status and during the "stand-by" status.

During the "on" state:

-

the 1 digit display is off.

-

the 3 digit display:

-

will display the blast chilling end temperature if a temperature-controlled blast chilling cycle has been

selected or the deep freezing end temperature if a temperature-controlled deep freezing cycle has been

selected.

-

will display the blast chilling duration if a temperature-controlled blast chilling cycle has been selected or

the deep freezing duration if a temperature-controlled deep freezing cycle has been selected.

-

the 4 digit display:

-

will display the work set-point during blast chilling if temperature-controlled blast chilling has been

selected or the work set-point during deep freezing if temperature-controlled deep-freezing has been

selected.

-

will be off if time-controlled blast chilling or time-controlled deep freezing has been selected.

During the "run" state:

-

the 1 digit display shows the program number if there is one in progress.

-

the 3 digit display:

-

will show the temperature detected by the needle probe if a temperature-controlled blast chilling or deep

freezing cycle is in progress

-

will display the residual blast chilling time if time-controlled blast chilling is in progress or the residual

deep freezing time if time-controlled deep freezing is in progress