Report Configuration

To configure reports, select Config from the Edit menu. The Program
Setup window displays:

The Single report options cover all ports and are overwritten each time
the reports are generated. The Multiple report options generate a
separate report for each port, and each report file is appended each
time the report is generated.

For Hour reports, use the Single and Multiple droplists to select
whether you are generating single or multiple reports, or both. For
each report type, select from the following types of data to include:

None: no report is generated.

Hour Data: only variables with “Hour” in the name are included.

All Data: all variables are included.

View Data: only variables that appear on-screen are included.

The External Program field is used to enter a command line to run
another program after the hourly reports have been generated. For
example, you can use this to run a batch file that performs custom
report processing. The Test button causes the command line to be
executed immediately.