Comtrol DM Primo for Pair Connect and Raw Connect Methods User Manual
Using devicemaster, Primo for pair connect and raw connect methods
Table of contents
Document Outline
- Table of Contents
- Overview
- Pair Connection Mode
- Pair Connection (Master)
- 1. From the Start menu, select the Run command.
- 2. Type Telnet plus the master Primo IP address, and select the OK button.
- 3. Confirm that it is a vt100 session, and press the Enter key.
- 4. Use the arrow keys to select the serverConfig menu item, and press the Enter key. If you need ...
- 5. Press the Esc key to return to the menu. Use the arrow keys to select the OP_mode menu item, a...
- 6. Select the item in the Application list, and press the Enter key to display connection options.
- 7. Select the Pair Connection (Master) item from the pop-up list. Press the Enter key.
- 8. From the More setting list, highlight the Select for more setting item, and press the Enter key.
- 9. Review the following values, and make any changes if needed:
- 10. Press the Esc key twice to return to the menu. Select the Serialport option, and press the En...
- 11. Press the Esc key to return to the main menu. Select the Monitor option. Review the options.
- 12. Press the Esc key to return to the menu. Select the Restart option to save any changes.
- Pair Connection (Slave)
- 1. From the Start menu, select the Run command.
- 2. Type Telnet plus the slave Primo IP address, and select the OK button.
- 3. Confirm that it is a vt100 session, and press the Enter key.
- 4. Use the arrow keys to select the serverConfig menu item, and press the Enter key. Review the v...
- 5. Press the Esc key to return to the menu. Use the arrow keys to select the OP- mode menu item a...
- 6. Select an item in the Application list, and press the Enter key to display connection options.
- 7. Use the arrow keys to select the Pair Connection (Slave) item, and press the Enter key.
- 8. From the More setting list, highlight the Select for more setting item, and press the Enter key.
- 9. Review the following values:
- 10. Press the Esc key to return to the main menu. Select the Serialport option. Review the values...
- 11. Press the Esc key to return to the menu. Select the Monitor option. Review the options.
- 12. Press the Esc key to return to the menu. Select the Restart option to save any changes.
- Pair Connection (Master)
- Raw Connection Mode
- TCP Server
- 1. From the Start menu, select the Run command.
- 2. Type Telnet plus the Primo IP address, and select the OK button.
- 3. Confirm that it is a vt100 session, and press the Enter key.
- 4. Use the arrow keys to select the serverConfig menu item, and press the Enter key. Review the v...
- 5. Press the Esc key to return to the menu. Use the arrow keys to select the OP_mode menu item, a...
- 6. Select the an item on the Application list, and press the Enter key to display the connection ...
- 7. Select the Raw Connection (TCP Server) item from the pop-up box. Press the Enter key.
- 8. From the More Setting list, highlight the Select for more setting item, and press the Enter key.
- 9. Set up a TCP port number, Destination IP address, Inactivity time, and TCP alive check time, a...
- 10. Press the Esc key twice to return to the main menu. Select the Monitor option.
- 11. Review the options and make any desired changes.
- 12. Press the Esc key to return to the menu. Select the Restart option to save any changes.
- TCP Client
- 1. From the Start menu, select the Run command.
- 2. Type Telnet plus the Primo IP address, and select the OK button.
- 3. Confirm that it is a vt100 session, and press the Enter key.
- 4. Use the arrow keys to select the serverConfig menu item, and press the Enter key. Review the v...
- 5. Press the Esc key to return to the menu. Use the arrow keys to select the OP_mode menu item, a...
- 6. Select an item on the Application list and press the Enter key to display the connection options.
- 7. Select the Raw Connection (TCP Client) item from the pop-up box. Press the Enter key to displa...
- 8. From the More Setting list, highlight the Select for more setting item, and press the Enter key.
- 9. Set up a TCP port number, Destination IP address, Inactivity time, and TCP alive check time, a...
- 10. Press the Esc key twice to return to the menu. Select the Monitor option.
- 11. Review the options, and make any desired changes.
- 12. Press the Esc key to return to the menu. Select the Restart option to save any changes.
- TCP Server
- Raw Connection - UPD
- UDP Server
- 1. From the Start menu, select the Run command.
- 2. Type Telnet plus the Primo IP address, and select the OK button.
- 3. Confirm that it is a vt100 session, and press the Enter key.
- 4. Use the arrow keys to select the serverConfig menu item, and press the Enter key. Review the v...
- 5. Press the Esc key to return to the menu. Use the arrow keys to select the OP_mode menu item, a...
- 6. Select the an item on the Application list, and press the Enter key to display the connection ...
- 7. Select the Raw Connection (UDP Server/Client) item from the pop-up box. Press the Enter key.
- 8. Highlight the Select for more settings item in the More setting list, and press the Enter key ...
- 9. Consider the following parameters. When you finish entering the desired parameters, press the ...
- Serial to Ethernet
- Ethernet to Serial (Optional)
- Data packing (Optional)
- 10. Select the Serialport menu item, and press the Enter key. Review the parameters. Make sure th...
- 11. Press the Esc key to return to the main menu.
- 12. Select the Monitor menu item, and press the Enter key.
- 13. Press the Enter key to return to the main menu. Select the Restart menu item to restart and s...
- 14. You have to repeat this procedure for each client device.
- UDP Client
- 1. From the Start menu, select the Run command.
- 2. Type Telnet plus the first client Primo IP address and select the OK button. You have to repea...
- 3. Confirm that it is a vt100 session, and press the Enter key.
- 4. Use the arrow keys to select the serverConfig menu item, and press the Enter key. Review the v...
- 5. Press the Esc key to return to the menu. Use the arrow keys to select the OP_mode menu item, a...
- 6. Select the an item on the Application list, and press the Enter key to display the connection ...
- 7. Select the Raw Connection (UDP Server/Client) item from the pop-up box. Press the Enter key to...
- 8. From the More setting list, highlight the Select for more settings item, and press the Enter k...
- 9. Clear all the fields except for the Port and Local listening Port fields which you can keep at...
- 10. Press the Esc key to return to the main menu.
- 11. Select the Monitor menu item, and press the Enter key.
- 12. Press the Enter key to return to the main menu. Select the Restart menu item to restart the d...
- 13. You have to repeat this procedure for each client device.
- UDP Server
- Telnet Console
- Index