KEYENCE AutoID User Manual
Page 39

3-7
3-3
Registering Devices and Saving Projects
MANAGING PROJECTS
3
3
The [ID registration] dialog box is displayed. Enter the ID and click the "OK" button.
• AutoID Navigator automatically enters a serial number as the ID to prevent IDs
from being duplicated. When manually changing IDs, take care to prevent the
ID from duplicating another ID.
• When registering the NX-50CL, set the number of occupied stations and cyclic
setting. The NX-50CL occupies two to four stations depending on its settings.
• The ID set here can also be changed later on.
"Renaming devices and changing IDs" (page 3-8)
4
Click the registered controller, select the head or barcode reader to be added to the project
as slaves, and click the "Regist" button.
When connecting multiple controllers (slave devices) to a master device, click the slave device to
add to the master device, select the controller and click the "Regist" button.
The following controllers can be connected to the master:
• Only one type of controller can be registered to a single master unit. An NX-
50DN cannot be registered to a master unit to which an NX-50CL is registered.
• When the exclusive communication unit (N-48) is used, the head is connected
directly under the N-410.
Note
Click
to select the number of
stations from the list.
• N-410
NX-50RS
• Master unit
NX-50CL or NX-50DN
Note