2 test function, Test function screen, 2 test function -3 – KEYENCE AutoID User Manual
Page 109: Test function screen -3, Test function -3, Test function

TEST
6
6-3
6-2
Test Function
AutoID Navigator has a "test function" for verifying whether or not transmission and reception of
data with each device is normal. Using this "test function" allows you to verify the communication
status between the head and IC tag, and the code reading status.
Test Function Screen
With AutoID Navigator's test function you can test operation of the
RF-500 Series, BL Series,
and SR Series.
The test function is started up by clicking
.
Item
Description
Target:
Select the device to be tested from the pull-down menu.Devices that are not
connected are not displayed.
Test mode
Displays the tests that can be executed on the selected device.
RF-500 Series: Communication stability test, communication count
measurement test, execution time measurement, noise
environment measurement
BL Series:
Reading rate measurement, tact measurement
SR-500 Series: Reading rate measurement, tact measurement, code position
measurement
* For the test mode of each device, refer to its user’s manual.
Start button/End button
Clicking "Start" button starts the test.Once the test starts, the button changes
to "End". To end the test, click the "End" button.
Result
Displays the history of test results. The latest data is displayed outside this
field depending on the content of the test.
Save csv log
Saves the history data of the test to be executed in the CSV format. Click this
button before receiving data.
Clear buffer
Clicking this button clears the test result history.