Electrical: deck wing lift, Cub cadet commercial z-wing – Cub Cadet Z-Wing User Manual
Page 81
Cub Cadet Commercial Z-Wing
77
33.
ELECTRICAL: DECK WING LIFT
33.1. The deck wing lift switch has a constant ground
to spade #6 (black wire). Spade #2 (red wire/
black trace) receives power whenever the key
switch is in any position other than OFF.
See Figure 33.1.
33.2. Rocking the switch in one direction closes con-
tacts joining 1 to 2 (Y) and 5 to 6 (R), connecting
power to terminal 2 and ground to terminal 5.
See Figure 33.2.
Figure 33.1
1
2
5
6
8
4
Figure 33.2
1 5
2 6
4 8
1 5
2 6
4 8
DOWN UP
33.3. Rocking the switch in the opposite direction
closes contacts joining 2 to 4 (R) and 6 to 8 (Y),
connecting power to terminal 4 and ground to
terminal 8. See Figure 33.3.
33.4. Rocking the switch in the opposite direction
closes contacts joining 2 to 4 (R) and 6 to 8 (Y),
connecting power to terminal 4 and ground to
terminal 8.
33.5. Jumper wires between terminals 4&5 and 1&8
reverse the polarity to drive the motor the oppo-
site direction.
33.6. The lift motor extends an actuator to lower the
wings, and retracts to raise the wings.
See Figure 33.6.
Figure 33.3
1 5
2 6
4 8
1 5
2 6
4 8
DOWN UP
+
-
+
-
Figure 33.6