General Configuration Screen
2M46-04R/2M46-04RDC User’s Guide
5-27
2.
Use the SPACE bar or BACKSPACE to step through the available
settings until the operation you require displays.
available settings and their corresponding applications.
3.
Press ENTER to accept the application.
4.
Use the arrow keys to highlight SAVE at the bottom of the screen, then
press the ENTER key. When the message “SAVED OK” displays, the
edits are saved.
Table 5-3
COM Port Application Settings
Setting
Application
LM
Local Management Session
UPS
APC Power Supply SNMP Proxy
!
CAUTION
When the COM port is configured to perform the UPS
application, all future LM connections must be made by a Telnet
connection. Ensure that the device has a valid IP address
before saving changes to the COM port application. If the
device does not have a valid IP address and the changes are
saved, refer to
for instructions on clearing NVRAM
in order to reestablish COM port communications.
!
CAUTION
When the COM port is configured to perform the UPS
application, all future Local Management connections must be
made by establishing a Telnet connection to the device. Ensure
that the device has a valid IP address before saving changes to
the COM port application. If the device does not have a valid IP
address and the changes are saved, refer to
for
instructions on clearing NVRAM in order to reestablish COM
port communications.