Page 104: Section 5.17

background image

Chapter 5: Local Management

5-56

2M46-04R/2M46-04RDC User’s Guide

5.17

BROADCAST SUPPRESSION SCREEN

The Broadcast Suppression screen,

Figure 5-22

, allows the user to set a

desired limit of receive broadcast frames that are switched out to the other
interfaces. This feature limits the amount of broadcast packets to the
threshold setting (1 second) and drops all other broadcast packets until the
1 second threshold elapses. This screen also provides statistics about the
broadcast activity on ports 1 through 4.

To access the Broadcast Suppression screen from the Device Specific
Configuration Menu screen, use the arrow keys to highlight the
BROADCAST SUPPRESSION menu item and press ENTER. The
Broadcast Suppression screen displays.

Figure 5-22

Broadcast Suppression Screen

NOTE

The Broadcast Suppression screen will display only if the
operational mode of the device has been set to 802.1D
SWITCHING or 802.1Q SWITCHING. Refer to

Section 5.7.9

,

Setting the Operational Mode

for instructions on configuring

the device to operate in this mode.

Firmware Revision: XX.XX.XX

Broadcast Suppression

2314-56

Device Type: 2M46-04R

BOOTPROM Revision: XX.XX.XX

Port #

1

2

3

4

Time Since Peak

999:23:59

999:23:59

999:23:59

999:23:59

Peak Rate

150000

150000

150000

150000

Threshold

150000

150000

150000

150000

2M46-04R LOCAL MANAGEMENT

Event Message Line

Total RX

12345678910

12345678910

12345678910

12345678910

Reset Peak

[NO]

[NO]

[NO]

[NO]

RETURN

RETURN

SAVE

EXIT