Chapter 3: Installation

3-4

2M46-04R/2M46-04RDC User’s Guide

3.3.2

2M46-04R and 2M46-04RDC Rackmount
Installation

Guidelines for the Rackmount Installation

The installation site must be within reach of the network cabling and meet
the requirements listed below:

An appropriate grounded power receptacle must be located within
seven feet of the device. (This requirement does not apply to the
2M46-04RDC.)

Maintain a temperature of between 5

°

C (41

°

F) and 40

°

C (104

°

F) at

the installation site with fluctuations of less than 10

°

C (18

°

F) per hour.

To install the 2M46-04R/04RDC in a 19-inch rack, Cabletron Systems
includes an accessory kit containing the rackmount brackets, mounting
screws, and a strain-relief bracket for cable management.

Attaching the Strain-Relief Bracket

Attach the strain-relief bracket to the front of the 2M46-04R/04RDC as
follows:

1.

Locate the strain-relief bracket and four 8-32 x 3/8-inch pan-head
screws in the rackmount kit.

2.

Place the 2M46-04R/04RDC upside down (as shown in

Figure 3-2

) on

a clean flat surface. Then attach the strain-relief bracket to the bottom
of the 2M46-04R/04RDC using the four 8-32 x 3/8-inch pan-head
screws.

WARNING

Before installing the 2M46-04R/04RDC into a rack, ensure that
the rack supports the device(s) without compromising the
stability of the rack. Otherwise, personal injury and/or
equipment damage may result.

!

CAUTION

To ensure proper ventilation and prevent overheating, leave a
minimum clearance space of 5.1 cm (2.0 in) at the left, right,
and rear of the 2M46-04R.

!

CAUTION

Do not attempt to attach the strain-relief bracket with screws
other than the 8-32 x 3/8-inch screws included with the
2M46-04R/04RDC. Use of longer screws may damage the unit.