7 general configuration screen, General configuration screen -16, Section 5.7 – Cabletron Systems 2M46-04R User Manual
Page 64
Chapter 5: Local Management
5-16
2M46-04R/2M46-04RDC User’s Guide
5.7
GENERAL CONFIGURATION SCREEN
The General Configuration screen,
, allows the user to, among
other things, set the system date and time, IP address and subnet mask, the
default gateway, the TFTP gateway IP address, the operational mode, and
the COM port configuration.
To access the General Configuration screen from the Device
Configuration Menu screen, use the arrow keys to highlight the
GENERAL CONFIGURATION menu item and press ENTER. The
General Configuration screen displays.
Figure 5-9
General Configuration Screen
The following briefly explains each General Configuration screen field:
MAC Address (Read-Only)
Displays the base physical address of the 2M46-04R.
IP Address (Modifiable)
Displays and allows the user to set the IP address for the 2M46-04R. To
set the IP address, refer to Section 5.7.1. The IP address can also be set
through Runtime IP Address Discovery as previously described in
Firmware Revision: XX.XX.XX
General Configuration
2314-15
Device Type: 2M46-04R
BOOTPROM Revision: XX.XX.XX
MAC Address:
IP Address:
Subnet Mask:
Default Gateway:
TFTP Gateway IP Addr:
Device Date:
Device Time:
Screen Refresh Time:
Screen Lockout Time:
Device Uptime XX D XX H XX M
Com 1: [ENABLED] Application: [LM]
Clear NVRAM: [NO] IP Fragmentation [ENABLED ]
Operational Mode: [802.1D SWITCHING]
2M46-04R LOCAL MANAGEMENT
Event Message Line
RETURN
SAVE
00-00-ID-00-00-00
0.0.0.0
0.0.0.0
NONE DEFINED
0.0.0.0
11/29/97
14:23:00
03 sec.
15 min.
EXIT