10 configuring the com port, 10 configuring the com port -25, General configuration, as described in – Cabletron Systems 2M46-04R User Manual
Page 73: Section 5.7.10, Refer to the ups
General Configuration Screen
2M46-04R/2M46-04RDC User’s Guide
5-25
5.7.10
Configuring the COM Port
Upon power up, the COM port is configured to the default settings of
ENABLED and LM.
The 2M46-04R COM port supports the following applications:
•
Local Management connections
•
American Power Conversion Uninterruptible Power Supply (UPS)
connections
To configure the COM port, proceed as follows:
1.
Use the arrow keys to highlight the Com 1 field.
2.
Press the SPACE bar to choose either ENABLED or DISABLED.
ENABLED allows the COM port to be connected to the terminal and
used for a particular application. DISABLED disables the COM port
connection to the terminal.
!
CAUTION
Before altering the COM port settings, ensure that a valid IP
address is set. Refer to
. Read this entire COM
port configuration section before altering the COM port
settings.
!
CAUTION
Do NOT disable or alter the settings of the COM port while
operating the current Local Management connection through a
terminal. Altering the COM port settings disconnects the Local
Management terminal from the port, and ends the Local
Management session. If the 2M46-04R was previously
assigned a valid IP address, reenter Local Management by
establishing a Telnet connection to the device. If the device
does not have a valid IP address and the COM port has been
disabled or the settings changed, reset NVRAM on the
2M46-04R (refer to
) to reestablish COM port
communications.
!
CAUTION
If the COM port is configured without a valid IP address, the
screen shown in
displays.
Do not continue unless the outcome of the action is fully
understood. If the Warning screen displays, continue on to
step 3, otherwise, proceed to step 4.