beautypg.com

5 connecting to the network, 1 connecting a utp segment to the fe-100tx, Connecting to the network -11 3.5.1 – Cabletron Systems 2M46-04R User Manual

Page 35: Connecting a utp segment to the fe-100tx -11

background image

Connecting to the Network

2M46-04R/2M46-04RDC User’s Guide

3-11

3.5

CONNECTING TO THE NETWORK

This section provides the procedures for connecting UTP and fiber optic
segments from the network or other devices to the 2M46-04R.

Ports 1 and 2 support FE-100TX, FE-100FX, or FE-100F3 Fast Ethernet
Interface Modules. Refer to

Section 3.5.1

to make a UTP cable

connection to an optional FE-100TX in port slot 1 or 2. Refer to

Section 3.5.2

to make an SC fiber optic cable connection to an optional

FE-100FX or FE-100F3 in port slot 1 or 2.

Refer to the associated High Speed Interface Module user’s guide to make
connections to an optional High Speed Interface Module installed in the
HSIM slots.

3.5.1

Connecting a UTP Segment to the FE-100TX

An FE-100TX installed in port slot 1 and/or 2 has an internal crossover. If
you need a crossover, set the Fast Ethernet Interface Module crossover
switch shown in

Figure 3-9

to the crossed over position marked with an

X. If you do not need a crossover, set the Fast Ethernet Interface Module
crossover switch shown in

Figure 3-9

to the straight-through (not crossed

over) position, marked with an =.

NOTE

The 2M46-04RDC sounds an audible alarm if there is a polarity
reversal. If the alarm sounds, turn off the 48/60 Vdc power
source to that power supply. Then reverse the positive and
negative leads to the dc input power strip of that power supply.
Restore power from the 48/60 Vdc power source. Press the
on/off switch to on. If the alarm sounds again, press the power
switch to off and contact the Cabletron Systems Global Call
Center. Refer to

Section 1.5

.

NOTE

If the 2M46-04R is being installed in a network using
SmartTrunking, there are rules concerning the network cable
and port configurations that must be followed for
SmartTrunking to operate properly. Before connecting the
cables, refer to the Cabletron Systems

SmartTrunk User’s

Guide for the configuration information.

This manual is related to the following products: