beautypg.com

2 installing options, 3 installing the 2m46-04r, 1 tabletop or shelf installation – Cabletron Systems 2M46-04R User Manual

Page 26: Installing options -2, Installing the 2m46-04r -2 3.3.1, Tabletop or shelf installation -2

background image

Chapter 3: Installation

3-2

2M46-04R/2M46-04RDC User’s Guide

3.2

INSTALLING OPTIONS

If the 2M46-04R is to be installed with an optional Fast Ethernet Interface
Module, refer to

Appendix C

for installation instructions. The installation

instructions for the HSIMs are in the associated HSIM user’s guide.

3.3

INSTALLING THE 2M46-04R

The 2M46-04R may be installed on a tabletop, shelf, or in a 19-inch rack.

Section 3.3.1

describes a tabletop or shelf installation and

Section 3.3.2

describes the rackmount installation.

3.3.1

Tabletop or Shelf Installation

Tabletop and shelf installations must be within reach of the network
cabling and meet the requirements listed below:

Locate the 2M46-04R within seven feet of an appropriately grounded
power receptacle that meets the power supply requirements listed in

Appendix A

,

Specifications

. (This requirement does not apply to the

2M46-04RDC.)

In a shelf installation, the shelf must support 13.6 kg (30 lb) of static
weight for all devices.

Maintain a temperature of between 5°C (41°F) and 40°C (104°F) at
the installation site with fluctuations of less than 10°C (18°F) per hour.

NOTE

Install any optional equipment before proceeding to

Section 3.3

.

To prevent possible damage to the unit, do NOT connect power
to the 2M46-04R until instructed to do so.

!

CAUTION

Maintain a 2-inch clearance from the left, right, and rear sides
of the device to provide adequate ventilation and prevent
overheating.

This manual is related to the following products: