FE-100F3

The FE-100F3 shown in

Figure B-3

uses an SC style connector that

supports single mode fiber optic cabling. Specifications for the FE-100F3
are listed in

Table B-2

, below.

Figure B-3

FE-100F3

Table B-2

Transmitter Power

Cable Type

Worst Case Budget

Typical Budget

8/125 µm fiber optic

>10.0 dB

<10.0 dB

12.5/125 µm fiber optic

>10.0 dB

<10.0 dB

NOTE

The transmitter power levels and receive sensitivity levels listed
are peak power levels after optical overshoot. A peak power
meter must be used to correctly compare the values given
above to those measured on any particular port. If power levels
are being measured with an average power meter, add 3 dB to
the measurement to compare the measured values to the
values listed above.