RMON Statistics Screen

2M46-04R/2M46-04RDC User’s Guide

5-69

Total Octets (Read-only)

This field displays the total number of octets (bytes) of data, including
those in bad frames, received on this interface.

64 Octets (Read-only)

Displays the total number of frames including bad frames, received that
were 64 bytes in length (excluding framing bits, but including FCS bytes).

65 - 127 Octets (Read-only)

Displays the total number of frames, including bad frames, received that
were between 65 and 127 bytes in length (excluding framing bits, but
including FCS bytes).

128 - 255 Octets (Read-only)

Displays the total number of frames, including bad frames, received that
were between 128 and 255 bytes in length (excluding framing bits, but
including FCS bytes).

256 - 511 Octets (Read-only)

Displays the total number of frames, including bad frames, received that
were between 256 and 511 bytes in length (excluding framing bits, but
including FCS bytes).

512 - 1023 Octets (Read-only)

Displays the total number of frames, including bad frames, received that
were between 512 and 1023 bytes in length (excluding framing bits, but
including FCS bytes).

1024 - 1518 Octets (Read-only)

Displays the total number of frames, including bad frames, received that
were between 1024 and 1518 bytes in length (excluding framing bits, but
including FCS bytes).

Index [

nn] (Selectable)

This field is used to enter an index number for viewing statistics. For
instructions on how to use this command refer to

Section 5.21.1

.

CLEAR COUNTERS

This command is used to reset all statistic counters to zero. For details on
how to use this field, refer to

Section 5.21.2

.