0 print formatting, 1 print formatting commands, Print formatting – Rice Lake Static Weighing User Manual
Page 60

56
CW-90/90X Checkweigher
7.0
Print Formatting
The CW-90/CW-90X provides seven print formats,
GFMT, NFMT, ACC.FMT, STRM.FM, BUS.FMT, HDRFMT1
and
HDRFMT2
. These determine the format of the
printed output when the
key is pressed or when a
KPRINT
EDP command is received. The
GFMT
and
NFMT
will print to all ports assigned as
DEMAND
in the
TRIGGE
parameter, based on whether a tare is in the
indicator. The
ACCFMT
will print to all
DEMAND
ports
when the
ACCUM
is displayed. The
SFMT
will be sent
as a
STREAM
if
TRIGGE
is set to
STREAM
on any port.
The
HDRFMT
s must be called from another format.
Each print format can be customized to include up to
300 characters of information, such as company name
and address, on printed tickets. You can use the
indicator front panel (
PFORMT
menu), EDP commands,
or the Revolutionconfiguration utility to customize the
print formats.
Note
Print formats are limited to 300 characters.
Press the down arrow to cycle to the previous
character. Press the up arrow to cycle to the
next character. To send a decimal point, enclose it in
brackets e.g., <.> or cycle through the characters until the
decimal point is displayed.
7.1
Print Formatting Commands
Table 7-1 lists commands you can use to format the
gross, net and count print formats. Commands included
in the format strings must be enclosed between < and >
delimiters. Any characters outside of the delimiters are
printed as text on the ticket. Text characters can include
any ASCII character that can be printed by the output
device.
Table 7-1. Print Format Commands
Command
Description
Gross weight in displayed units
Net weight in displayed units
Tare weight in displayed units
Accumulated weight in displayed units
Status of over/under/accept. O=Over,
U=Under, A=Accept space=Zero band
Over value
Under value
Target value
Loaded ID number
Description 1
Description 2
Units
Tare
Number of accumulator events (5-digit
counter)
Date of last accumulator event
Time of last accumulator event
Unit ID number
Consecutive number
New line (nn = number of termination (
Space (nn = number of spaces)*
Toggle weight data format (formatted/
unformatted)**
Time
<nnn>
ASCII character (nnn - decimal value of ASCII
character). Used for inserting control
characters (STX for example) in the print
stream.
Date
Time & Date
Header 1
Header 2
Gross, net, and tare weights are 8 digits in length, including
sign and decimal point, followed by a space and a one- to
five-digit units identifier. Total field length with units identifier
is 10-14 characters. Depending on what units are
configured, the units identifier will be lb/oz, lb, oz, g, or kg.
Gross, net, tare, and accumulator weights can be printed in
any configured weight units by adding the following
modifiers to the gross, net, tare, and accumulator weight
commands: /P (primary units), /D (displayed units), /S
(secondary units), /T (tertiary units). If not specified, the
current displayed units (/D) is assumed. Example: To format
a ticket to show net weight in secondary unitsm, use the
following command:
ID and consecutive number (CN) fields are 1–6 characters in
length, as required.
* If nn is not specified, 1 is assumed. Value must be in the
range 1–99.
** After receiving an SU command, the indicator sends
unformatted data until the next SU command is received.
Unformatted data omits decimal points, leading and trailing
characters.
Command
Description
Table 7-1. Print Format Commands