3 featur menu, regula / indust submenu, Featur menu, regula / indust submenu – Rice Lake Static Weighing User Manual
Page 31

Configuration
27
3.4.3
FEATUR Menu, REGULA / INDUST Submenu
REGULA
SNPSHT
DISPLY
INDUST
SCALE
HTARE
NO
YES
ZTARE
NO
YES
KTARE
YES
NO
MTARE
REMOVE
REPLAC
NOTHN
NTARE
NO
YES
CTARE
YES
NO
PRTMOT
NO
YES
PRTPT
NO
YES
PRTHLD
NO
YES
HLDWGH
NO
YES
MOTWGH
NO
YES
AGENCY
NTEP
INDUST
NONE
OIML
OVRBAS
CALIB
SCALE
REGION
CANADA
CHKWGH
Only displayed if INDUST is selected
from the AGENCY parameter
UID
CONSC#
PASSWD
STNDBY
KEYLCK
RECALL
SCALE
FEATUR
SERIAL
DIGI/O
PFORMT
VERS
CONFIG
EXIT
T&D
TEST
SETUP
AUDIT
XXXXXXX
CALIBR
BRIGHT
ACCUM
Only displayed if
turned on
from Setup menu
ID
Only displayed if
turned on
from Setup menu
RTARE
YES
NO
Figure 3-9. FEATUR Menu, REGACY/INDUST Submenu
FEATUR Menu, REGULA / INDUST Submenu
Parameter
Choices
Description
Level 4, REGULA / INDUST submenu
SNPSHT
DISPLY
SCALE
Display or Scale weight source.
HTARE
NO, YES
Allow tare in display hold.
ZTARE
NO, YES
Remove tare on ZERO.
KTARE
YES, NO
Always allow keyed tare.
MTARE
REPLAC
REMOVE
NOTHIN
Multiple tare action.
NTARE
NO, YES
Allow negative or zero tare.
CTARE
YES, NO
Allow CLEAR key to clear tare/accumulator.
RTARE
YES, NO
Round push button tare to the nearest display division.
PRTMOT
NO, YES
Allow print while in motion.
PRTPT
NO, YES
Add PT to keyed tare print.
PRTHLD
NO, YES
Print during display hold.
HLDWGH
NO, YES
Allow weighment during display hold.
MOTWGH
NO, YES
Allow weighment in motion.
Table 3-6. REGACY / INDUST Submenu Parameters