Rice Lake Static Weighing User Manual
Page 56

52
CW-90/90X Checkweigher
REG.ZTARE
Remove tare on ZERO
NO, YES
REG.RTARE
Round push button tare to nearest
display division
NO, YES
REG.MOTWGH
Allow weighment in motion
NO, YES
REG.OVRBASE
Zero base for overload calculation
CALIB ZERO, SCALE ZERO
REG.PRTMOT
Allow print while in motion
NO, YES
REG.PRINTPT
Add PT to keyed tare print
NO, YES
REG.PRTHLD
Print during display hold
NO, YES
REG.SNPSHOT
Display or Scale weight source
DISPLAY, SCALE
REGWORD
Regulatory word
GROSS, BRUTTO
SD
Set date
MMDDYY, DDMMYY, YYMMDD, or YYDDMM. Enter six-digit
date using the year-month-day order specified for the
DATEFMT parameter, using only the last two digits of the year.
ST
Set time
hhmm (enter using 24-hour format)
TIMEFMT
Time format
12HOUR, 24HOUR
TIMESEP
Time separator
COLON, COMMA
ZERONLY
Disable all keys except ZERO
OFF, ON
Table 6-7. PFORMT Serial Commands
Command
Description
Values
GFMT.FMT
Gross demand print format string
See Section 7.0 on page 56 for information about demand print
format strings.
NFMT.FMT
Net demand print format string
ACC.FMT
Accumulator print format string
BUF.FMT
Buffer print format string
STRM.FMT
Streaming Format
See Section 6.2 on page 53 for information about custom stream
formatting.
HDRFMT1
Header 1 Format
Enter the data you want displayed in Header 1
HDRFMT2
Header 2 Format
Enter the data you want displayed in Header 2
Table 6-8. DIG I/O Serial Commands
Command
Description
Values
DIO#b
Digital input function
OFF, ZERO, NT/GRS, TARE, UNITS, PRINT,
ACCUM, TIMDATE, ESC, CLEAR, DSPTAR,
IDKEY, KEY0–KEY9, KEYDP, ENTER, NAVUP,
NAVDN, NAVLFT, NAVRGT, KBDLOC, HOLD,
CLRCN, GROSS, NET, PRIM, SEC, CLRTAR,
CLRACC, TRIGGER
DIO#b
Digital output function
OVER, UNDER, ACCEPT, ZEROBD
DIO.TIMER#b
Digital output timer function
DIO.TRIP#x
Digital output trip functionality
STABLE
FRERUN
Digital inputs and outputs are specified by bit number
Command
Description
Values
Table 6-6. FEATURE Serial Commands (Continued)