beautypg.com

Dell POWEREDGE M1000E User Manual

Page 592

background image

592

Fabric OS Administrator’s Guide

53-1002745-02

LSAN zone configuration

24

3. Enter the zoneCreate command to create the LSAN lsan_zone_fabric75, which includes the

host.

switch:admin> zonecreate "lsan_zone_fabric75", "10:00:00:00:c9:2b:c9:0c"

4. Enter the zoneAdd command to add Target A to the LSAN.

FID75Domain5:admin> zoneadd "lsan_zone_fabric75", "50:05:07:61:00:5b:62:ed"

5. Enter the cfgAdd or cfgCreate and cfgEnable commands to add and enable the LSAN

configuration.

switch:admin> cfgadd "zone_cfg", "lsan_zone_fabric75"
switch:admin> cfgenable "zone_cfg"
You are about to enable a new zoning configuration.
This action will replace the old zoning configuration with the
current configuration selected.
Do you want to enable 'zone_cfg' configuration (yes, y, no, n): [no] y
zone config "zone_cfg" is in effect
Updating flash …

6. Log in as admin to fabric2.

7. Enter the nsShow command to list Target A (50:05:07:61:00:5b:62:ed) and Target B

(50:05:07:61:00:49:20:b4).

switch:admin> nsshow
{
Type Pid COS PortName

NodeName TTL(sec)

NL 0508e8; 3;

50:05:07:61:00:5b:62:ed;

50:05:07:61:00:1b:62:ed; na

FC4s: FCP [IBM DNEF-309170 F90F]
Fabric Port Name: 20:08:00:05:1e:34:11:e5
Permanent Port Name: 50:05:07:61:00:5b:62:ed
NL 0508ef; 3;

50:05:07:61:00:49:20:b4;

50:05:07:61:00:09:20:b4; na

FC4s: FCP [IBM DNEF-309170 F90F]
Fabric Port Name: 20:08:00:05:1e:34:11:e5
Permanent Port Name: 50:05:07:61:00:49:20:b4

LSAN: Yes

The Local Name Server has 2 entries }

8. Enter the zoneCreate command to create the LSAN lsan_zone_fabric2, which includes the host

(10:00:00:00:c9:2b:6a:2c), Target A, and Target B.

switch:admin> zonecreate "lsan_zone_fabric2",
"10:00:00:00:c9:2b:c9:0c;50:05:07:61:00:5b:62:ed;50:05:07:61:00:49:20:b4"

9. Enter the cfgShow command to verify that the zones are correct.

switch:admin> cfgshow
Defined configuration:
zone: lsan_zone_fabric2
10:00:00:00:c9:2b:c9:0c; 50:05:07:61:00:5b:62:ed;
50:05:07:61:00:49:20:b4

Effective configuration:
no configuration in effect

10. Enter the cfgAdd and cfgEnable commands to create and enable the LSAN configuration.

switch:admin> cfgadd "zone_cfg", "lsan_zone_fabric2"
switch:admin> cfgenable "zone_cfg"
You are about to enable a new zoning configuration.