beautypg.com

Figure 42 – Dell POWEREDGE M1000E User Manual

Page 361

background image

Fabric OS Administrator’s Guide

361

53-1002745-02

Virtual Fabrics considerations for Traffic Isolation Zoning

12

Virtual Fabrics considerations for Traffic Isolation Zoning

This section describes how TI zones work with Virtual Fabrics. See

Chapter 10, “Managing

Virtual Fabrics,”

for information about the Virtual Fabrics feature, including logical switches and

logical fabrics.

TI zones can be created in a logical fabric like in regular fabrics, with the following exceptions:

The disable failover option is not supported in logical fabrics that use XISLs.
Although logical switches that use XISLs allow the creation of a TI zone with failover disabled,
this is not a supported configuration. Base switches do not allow the creation of a TI zone with
failover disabled.

To create a TI zone for a logical fabric that uses XISLs, you must create two TI zones: one in the
logical fabric and one in the base fabric. The combination of TI zones in the base fabric and
logical fabric sets the path through the base fabric for logical switches.

The TI zone in the logical fabric includes the extended XISL (XISL) port numbers, as well as the
F_Ports and ISLs in the logical fabric.

The TI zone in the base fabric reserves XISLs for a particular logical fabric. The base fabric TI zone
should also include ISLs that belong to logical switches participating in the logical fabric.

Figure 42

shows an initiator and target in a logical fabric (FID1). The dotted line indicates a

dedicated path between initiator and target. The dedicated path passes through the base fabric
over an XISL. (

Figure 42

shows only physical ISLs, not logical ISLs.) To create the TI zones for this

dedicated path, you must create a TI zone in the logical fabric (FID 1) and one in the base fabric.

FIGURE 42

Dedicated path with Virtual Fabrics

Figure 43

shows a logical representation of FID1 in

Figure 42

. To create the dedicated path, you

must create and activate a TI zone in FID1 that includes the circled ports shown in

Figure 43

.

= Dedicated Path

Chassis 1

Chassis 2

XISL

XISL

XISL

XISL

Domain 8

Domain 7

Base switch
Domain 2

LS2, FID3
Domain 6

LS1, FID1
Domain 5

Base switch
Domain 1

LS4, FID3
Domain 4

LS3, FID1
Domain 3

Domain 9

2

4

= Ports in the TI zones

6

7

12

1

8

5

3

8

17

15

16

14

13

11

10

9

Host

Target