beautypg.com

System configuration ~ processing, Filters – ClearOne XAP400 User Manual

Page 57

background image

51

System Configuration

~ Processing

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Ratio

Ratio changes the rate of compression applied to the input signal as the signal
exceeds the threshold level. The range is 1:1 to 1:20dB. Default is 1:1.

Attack

Attack determines how quickly compression is enabled. It is calibrated in
milliseconds. The range is 0 to 100ms in .5ms steps. Default is 10ms.

Release

Release determines how quickly compression is disabled. The range is 100ms to 2
seconds, in 5ms increments. Default is 500ms.

Input meter

This peak meter shows the level of the signal as it enters the compressor.

Compression meter

This peak meter shows the instantaneous compression value at a given time.

Filters

The Filter button on the selected Processing channel opens the Processing Filters
window. Here, you can configure all filters available in G-Ware: All Pass, Bessel,
Butterworth, CD Horn, High Pass, High Shelving, Linkwitz-Riley, Low Pass, Low
Shelving, Notch, and PEQ.

Figure 3.55. Processing Filters window