beautypg.com

Macro - macro execution/reporting, Master - expansion bus master mode, Max - maximum gain setting – ClearOne XAP400 User Manual

Page 134: Appendices ~ appendix e: serial commands, Argument details

background image

128

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendices

~ Appendix E: Serial Commands

MACRO - Macro Execution/Reporting

This command executes a specified macro or reports the last macro executed. There
are 255 macros that can be specified.
Command form: DEVICE MACRO [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

MACRO

Command form

Value

1-255 Value to execute user macros

Example:

#75 MACRO 1 On XAP 400 unit 5 (#75), Macro (MACRO) 1 is

run.

MASTER - Expansion Bus Master Mode

This command reports the mode of the unit. The mode can be Master or Slave.
Command form: DEVICE MASTER [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

MASTER

Command form

Value

1 = Master, 2 = Slave, Null = Current mode of the unit

Example:

#76 MASTER 2 On XAP 400 unit 6 (#76), the MASTER mode is

set to slave (2)

MAX - Maximum Gain Setting

This command changes or reports back the maximum gain setting for an input,

output or assignable processing block.

Command form: DEVICE MAX [Value]

Argument details

Name

Description

Units

Device

0—7 or * to select all units

MAX

Command form

Channel

See Groups and Channels, page 105

Group

I, O, M, P, L

Value

-65.00 to 20.00

dB

Null to return the current setting

Example:

#71 MAX 2 M 10 On XAP 400 unit 1 (#71), the maximum (MAX)

relative gain setting for mic (M) channel 2 is 10dB.

The response indicates

execution of the macro,

but does not indicate that

each command within the macro

was executed.

This setting will affect all

relative gain adjustments.