beautypg.com

Refsel - pa/aec reference select, Refset - reference channel setup, Ring - ring indication – ClearOne XAP400 User Manual

Page 144: Appendices ~ appendix e: serial commands, Argument details

background image

138

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendices

~ Appendix E: Serial Commands

REFSEL - PA/AEC Reference Select

This command selects/reports which output is used for each mic as a reference for

power amp adaptation mode and acoustic echo cancellation where applicable. There

can be only one selection per mixer.

Command form: DEVICE REFSEL [Ref. Group] [Ref. Channel]

Argument details

Name

Description

Device

0—7 or * to select all units

REFSEL

Command

Channel

1—4 (select mic input)

Ref. Group

0 = Output, E = Expansion bus

Ref. Channel

1—9, O—Z (select output or E-bus channel)

Example:

#70 REFSEL 1 O 8 On XAP 400 unit 7 (#70), the PA/AEC

reference REFSEL for mic channel 1 is output (O) 12.

REFSET - Reference channel setup

This command selects/reports the output the reference channel tracks.
Command form: DEVICE REFSET [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

REFSET

Command

Channel

1—4 (select Virtual Reference number)

Group

1—9 (select output channel to track)

Value

0 = none

Example:

#73 REFSET 2 4 On XAP 400 unit 3 (#73), virtual reference (2) will

track gain changes mde on output channel 4.

RING - Ring Indication

This command indicates a ringing line. This command is reportable only. It cannot

be queried or set.
Command form: DEVICE RING

Argument details

Name

Description

Device

0—7 or * to select all units

RING

Command

Channel

See Groups and Channels, page 105

Example:

#71 RING 1 On XAP 400 unit 1 (#71), the hybrid (1) will detect an

incoming RING.