Control/status connectors, Control/status a port pinout (female), Appendices ~ appendix b: pinouts – ClearOne XAP400 User Manual
Page 104
98
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Control/Status A Port Pinout (female)
Pin
Definable
Type
Default Description
1
Yes
Control
Lock front panel toggle
2
Yes
Status
Status of front panel lock
3
Yes
Control
Mute all mics toggle
4
Yes
Status
Status of mute all mics
5
Yes
C
Mute Output 9 toggle
6
Yes
S
Status of Output 9 mute
7
Yes
C
Mute Output 10 toggle
8
Yes
S
Status of Output 10 mute
9
Yes
C
Mute Output 11 toggle
10
Yes
S
Status of Output 11 mute
11
Yes
C
Mute Output 12 toggle
12
Yes
S
Status of Output 12 mute
13
Yes
C
Volume Up D Output 1 (1dB)
14
Yes
S
Not programmed
15
Yes
C
Volume Down D Output 1 (1dB)
16
Yes
S
Not programmed
17
No
S
Mic #1 Gate Status
18
No
S
Mic #2 Gate Status
19
No
S
Mic #3 Gate Status
20
No
S
Mic #4 Gate Status
21
No
S
Mic #5 Gate Status
22
No
S
Mic #6 Gate Status
23
No
S
Mic #7 Gate Status
24
No
S
Mic #8 Gate Status
25
No
Ground
Ground
Figure B.6. Control/Status Ports A, B
Control/Status connectors
The Control/Status connections are provided on two DB-25 connectors. These
connectors are labeled Control/Status A and Control/Status B and contain different
types of pins. The inputs on these connectors are internally pulled high and are
activated by connecting the pin to ground. The outputs are open collectors, which are
open when inactive and grounded when active. This allows the XAP 400 to control
and be controlled by a wide variety of external devices, including relays, lamps,
switches, and other equipment. Control pins on Control/Status A are momentary
while control pins on Control/Status B are latching.
Appendices
~ Appendix B: Pinouts
The first 16 pins on the
Control/Status Port A can
be programmed using
G-Ware software.