Cgroup - compressor group select, Chairo - chairman override mode, Appendices ~ appendix e: serial commands – ClearOne XAP400 User Manual
Page 119: Argument details

113
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
CGROUP - Compressor Group Select
This command selects/reports the setting of the compressor group on each assignable
processing channel.
Command form: DEVICE CGROUP
Argument details
Name
Description
Device
0—7 or * to select all units
CGROUP
Command form
Channel
range A—D (selects processing channel)
Value
0 = none, 1 = compressor group 1, 2 = compressor group 2,
3 = compressor group 3, 4 = compressor group 4,
null to return the current mode
Example:
#72 CGROUP A 2 On XAP 400 unit 2 (#72), the compression group
(CGROUP) for processing channel A is 2.
CHAIRO - Chairman Override Mode
This command selects/reports the setting of chairman override.
Command form: DEVICE CHAIRO
Argument details
Name
Description
Device
0—7 or * to select all units
CHAIRO
Command form
Channel
Range 1—4 (selects mic input)
Value
0 = Off, 1 = On, 2 = Toggle, Null to return current state
Example:
#77 CHAIRO 3 1 On XAP 400 unit 7 (#77), chairman override
(CHAIRO) for mic channel 3 is set on (1).