GRATIO - Gate Ratio Adjust

This command selects/reports the setting of the gate ratio.
Command form: DEVICE GRATIO [Value]

Argument details

Name

Description

Units

Device

0—7 or * to select all units

GRATIO

Command form

Channel

1—4 (select mic input)

Value

0 to 50

dB

Null to return current ratio

Example

: #72 GRATIO 1 15 On XAP 400 unit 2 (#72), the gate ratio

(GRATIO) for mic channel 1 is set to 15dB.

GREPORT - Gate Report

This command selects/reports the gate status.
Command form: DEVICE GREPORT

Argument details

Name

Description

Device

0—7 or * to select all units

GREPORT

Command form

Value

0 = Off, 1 = On, 2 = Toggle

Example:

#73 GREPORT 1 On XAP 400 unit 3 (#73), the gate reporting

(GREPORT) is set to on (1).

GRPSEL - Gating Group Select

This command selects/reports which gating group each input is assigned. There can
only be one selection per input.
Command form: DEVICE GRPSEL [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

GRPSEL

Command form

Channel

1—4 (selects mic input)

Value

A—D (selects gating group), Null to return current value

Example:

#74 GRPSEL 1 A On XAP 400 unit 4 (#74), mic channel 1 is

assigned to gating group (GRPSEL) A.