GRATIO - Gate Ratio Adjust
This command selects/reports the setting of the gate ratio.
Command form: DEVICE GRATIO
Argument details
Name
Description
Units
Device
0—7 or * to select all units
GRATIO
Command form
Channel
1—4 (select mic input)
Value
0 to 50
dB
Null to return current ratio
Example
: #72 GRATIO 1 15 On XAP 400 unit 2 (#72), the gate ratio
(GRATIO) for mic channel 1 is set to 15dB.
GREPORT - Gate Report
This command selects/reports the gate status.
Command form: DEVICE GREPORT
Argument details
Name
Description
Device
0—7 or * to select all units
GREPORT
Command form
Value
0 = Off, 1 = On, 2 = Toggle
Example:
#73 GREPORT 1 On XAP 400 unit 3 (#73), the gate reporting
(GREPORT) is set to on (1).
GRPSEL - Gating Group Select
This command selects/reports which gating group each input is assigned. There can
only be one selection per input.
Command form: DEVICE GRPSEL
Argument details
Name
Description
Device
0—7 or * to select all units
GRPSEL
Command form
Channel
1—4 (selects mic input)
Value
A—D (selects gating group), Null to return current value
Example:
#74 GRPSEL 1 A On XAP 400 unit 4 (#74), mic channel 1 is
assigned to gating group (GRPSEL) A.